Pendulum Impact Testing Machine
- Payment Type:
- L/C, T/T
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Shenzhen China |
---|---|
Payment Type: | L/C, T/T |
Product Description
Product Description
Description
WANCE offers this series of pendulum impact testing machine designed for determining the impact resistance of metallic materials under dynamic loading.
This series is engineered for maximum accuracy, simplicity of design, ease of operation and safety, and performs standard notched bar impact tests.
Equipped with force transducer, precise data sampling and measurement system, it fully satisfies instrumented impact tests complying with international standards.
Equipped with low temperature chamber, it can perform impact tests under temperature from ambient to -180°C
Standards
ASTM E23, ASTM E1820, ASTM E2298, ISO 148, EN10045,
GB/T 3808, GB/T 229, JJG145, JJG 609
Significance and use
Compared with traditional pendulum impact testing machine, instrumented type is more useful for accurate analysis of material property during crack, facilitating the engineers to understand the most fragile part of materials when developing new materials.In addition to providing an measure of total absorbed energy (Wt), instrumented testing enables the determination of characteristic force, energy, and displacement parameters, such as the pre-maximum force energy (Wm); the post maximum force energy; the general yield force (Fgy); the force at brittle fracture initiation (Fbf); the arrest force (Fa).
Wance is the leading R&D and manufacturing of instrumented impact testing system in China, and has experienced experts for force transducer design. Combined with our high speed data sampling system, Wance provides the full complement of solutions for laboratory, ranging from 0.1J for engineering plastic to 100,000J for steel DWTT test.
Machine structure
The basic model consists of a heavy steel base on which the specimen holder (anvil) and a heavy-duty cast steel upright are mounted.
Framework
The framework is processed with one body casting. Front and rear columns are symmetric with single beam support axis, with high stiffness and precision.
The framework is made from ductile cast iron with high strength and stiffness, and with good capability of vibration absorbing.
The seat mass is 822kg, 15 times than 750J pendulum mass (54.65), fully complying with standards that seat mass must be 12 times than pendulum mass.
Pendulum
Pendulum is designed with 3D CAD software, greatly ensuring the striking center accuracy and pendulum moment precision. High strength pendulum rod highly reduces vibration after impact.
Striking knife is tightened by wedge block, simple to change. Striking knife is available with R2 and R8, fully complying with ASTM, JIS, DIN, GB, ISO, EN and other standards.
Striking knife is made of anti-wearing high speed tool steel with hardening treatment, and hardness is larger than HRC60, with high strength, ductility and abrasion resistance.
Supports and anvils
Anvil shape is rhombus and can be used in any direction, meaning the using life is 4 times than traditional anvil.
The anvil material is high speed tooling steel CW6Mo5Cr4V2 after hardening treatment, and the hardness is larger than HRC60, with high strength, ductility and abrasion resistance.
It is very simple to change anvils with inner hexagon spanner. The anvil is machined by special process with high precision and good interchangeability.
Energy display system
Three types of energy display are available:
Ø Dial gauge: simple and direct to read impact energy
Ø Wide view touch screen
Ø Computer with test software
Safety system
This series of machine has fully closed protection shield to protect operator against specimen splitting during test, and to deny any access to the inside during test. Built-in door interlock further ensures operator safety. The protection shield is constructed with aluminum alloy profile for frame and fiber glass for easy observation. Split-type door design is simple to repair and change pendulum.
WANCE offers this series of pendulum impact testing machine designed for determining the impact resistance of metallic materials under dynamic loading.
This series is engineered for maximum accuracy, simplicity of design, ease of operation and safety, and performs standard notched bar impact tests.
Equipped with force transducer, precise data sampling and measurement system, it fully satisfies instrumented impact tests complying with international standards.
Equipped with low temperature chamber, it can perform impact tests under temperature from ambient to -180°C
Standards
ASTM E23, ASTM E1820, ASTM E2298, ISO 148, EN10045,
GB/T 3808, GB/T 229, JJG145, JJG 609
Significance and use
Compared with traditional pendulum impact testing machine, instrumented type is more useful for accurate analysis of material property during crack, facilitating the engineers to understand the most fragile part of materials when developing new materials.In addition to providing an measure of total absorbed energy (Wt), instrumented testing enables the determination of characteristic force, energy, and displacement parameters, such as the pre-maximum force energy (Wm); the post maximum force energy; the general yield force (Fgy); the force at brittle fracture initiation (Fbf); the arrest force (Fa).
Wance is the leading R&D and manufacturing of instrumented impact testing system in China, and has experienced experts for force transducer design. Combined with our high speed data sampling system, Wance provides the full complement of solutions for laboratory, ranging from 0.1J for engineering plastic to 100,000J for steel DWTT test.
Machine structure
The basic model consists of a heavy steel base on which the specimen holder (anvil) and a heavy-duty cast steel upright are mounted.
Framework
The framework is processed with one body casting. Front and rear columns are symmetric with single beam support axis, with high stiffness and precision.
The framework is made from ductile cast iron with high strength and stiffness, and with good capability of vibration absorbing.
The seat mass is 822kg, 15 times than 750J pendulum mass (54.65), fully complying with standards that seat mass must be 12 times than pendulum mass.
Pendulum
Pendulum is designed with 3D CAD software, greatly ensuring the striking center accuracy and pendulum moment precision. High strength pendulum rod highly reduces vibration after impact.
Striking knife is tightened by wedge block, simple to change. Striking knife is available with R2 and R8, fully complying with ASTM, JIS, DIN, GB, ISO, EN and other standards.
Striking knife is made of anti-wearing high speed tool steel with hardening treatment, and hardness is larger than HRC60, with high strength, ductility and abrasion resistance.
Supports and anvils
Anvil shape is rhombus and can be used in any direction, meaning the using life is 4 times than traditional anvil.
The anvil material is high speed tooling steel CW6Mo5Cr4V2 after hardening treatment, and the hardness is larger than HRC60, with high strength, ductility and abrasion resistance.
It is very simple to change anvils with inner hexagon spanner. The anvil is machined by special process with high precision and good interchangeability.
Energy display system
Three types of energy display are available:
Ø Dial gauge: simple and direct to read impact energy
Ø Wide view touch screen
Ø Computer with test software
Safety system
This series of machine has fully closed protection shield to protect operator against specimen splitting during test, and to deny any access to the inside during test. Built-in door interlock further ensures operator safety. The protection shield is constructed with aluminum alloy profile for frame and fiber glass for easy observation. Split-type door design is simple to repair and change pendulum.