Electrosurgical Generator (LCD) (Unt-2000ai)
- Payment Type:
- T/T
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | China |
---|---|
Payment Type: | T/T |
Product Description
Product Description
Highest output: 400W
Nine working modes:
Monopolar: Pure cut, blend1, blend2, blend3, spray coagulation, forced coagulation, soft coagulation
Bipolar: Bipolar coagulation, bipolar cut
The electrosurgical generator is used to control bleeding and surgical cutting in all general and open surgical procedures
Touch control panel, three-way power output, with different audible and visual indication during the process of outputting.
Patient return electrode monitoring system and Power Peak System that provides surgeons with improved performance at Lower power settings, minimizing the risk of tissue damage.
Memory function: Nine frequently used settings can be preset.
Applicable for Prostate Vaporizing Surgical Operation(TUR), perfectly used under water. The electrosurgical generator can be cooperated with, endoscope and laparoscope
Pencil Remoting Output. The output power can be controlled by the remoting control pencil.
Technical Specifications
Power: 220V± 22V, 50Hz± 1Hz(110V± 11V, 60Hz)
Operating frequency: A)Monopolar: 512kHz b) Bipolar: 1024kHz
Power rating: 1100VA± 10%
Nine working modes:
Monopolar Cut
A) Pure cut: 10W~400W( Load 800Ω )
B) Blend1: 1W~300W(Load 800Ω )
C) Blend2: 1W~200W(Load 800Ω )
D) Blend3: 1W~150W(Load 800Ω )
Monopolar Coag
E) Spray Coag: 1W~100W( Load 800Ω )
F) Forced Coag: 1W~120W( Load 800Ω )
G) Soft Coag: 1W~120W( Load 800Ω )
Bipolar
8) Bipolar Coagulation: 1W~70W( Load 100Ω )
9) Bipolar Cut: 1W~120W( Load 100Ω )
Power Consumption: ≤ 1100VA
Configuration Sheet
Electrosurgical Pencil 5PCS
Electrosurgical Pad 10PCS
Electrosurgical pad cable 1PC
Footswitch 1set
Bipolar Forceps and cable 1set
Nine working modes:
Monopolar: Pure cut, blend1, blend2, blend3, spray coagulation, forced coagulation, soft coagulation
Bipolar: Bipolar coagulation, bipolar cut
The electrosurgical generator is used to control bleeding and surgical cutting in all general and open surgical procedures
Touch control panel, three-way power output, with different audible and visual indication during the process of outputting.
Patient return electrode monitoring system and Power Peak System that provides surgeons with improved performance at Lower power settings, minimizing the risk of tissue damage.
Memory function: Nine frequently used settings can be preset.
Applicable for Prostate Vaporizing Surgical Operation(TUR), perfectly used under water. The electrosurgical generator can be cooperated with, endoscope and laparoscope
Pencil Remoting Output. The output power can be controlled by the remoting control pencil.
Technical Specifications
Power: 220V± 22V, 50Hz± 1Hz(110V± 11V, 60Hz)
Operating frequency: A)Monopolar: 512kHz b) Bipolar: 1024kHz
Power rating: 1100VA± 10%
Nine working modes:
Monopolar Cut
A) Pure cut: 10W~400W( Load 800Ω )
B) Blend1: 1W~300W(Load 800Ω )
C) Blend2: 1W~200W(Load 800Ω )
D) Blend3: 1W~150W(Load 800Ω )
Monopolar Coag
E) Spray Coag: 1W~100W( Load 800Ω )
F) Forced Coag: 1W~120W( Load 800Ω )
G) Soft Coag: 1W~120W( Load 800Ω )
Bipolar
8) Bipolar Coagulation: 1W~70W( Load 100Ω )
9) Bipolar Cut: 1W~120W( Load 100Ω )
Power Consumption: ≤ 1100VA
Configuration Sheet
Electrosurgical Pencil 5PCS
Electrosurgical Pad 10PCS
Electrosurgical pad cable 1PC
Footswitch 1set
Bipolar Forceps and cable 1set
Related Keywords