Electrosurgical Generator (LCD) Unt-2000A
- Payment Type:
- T/T
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | China |
---|---|
Payment Type: | T/T |
Product Description
Product Description
Highest output: 300W
Seven working modes:
Monopolar: Pure cut, blend1, blend2, contact coagulation, forced coagulation
Bipolar: Bipolar coagulation, bipolar cut
The electrosurgical generator is used to control bleeding and surgical cutting in all general and open surgical procedures.
Liquid Crystal Display, with different audible and visual indication during the process of outputting.
Patient return electrode monitoring system and Power Peak System that provides surgeons with improved performance at Lower power settings, minimizing the risk of tissue damage.
Applicable for Prostate Vaporizing Surgical Operation(TUR), perfectly used under water. The electrosurgical generator can be cooperated with, endoscope and laparoscope
Technical Specifications
Power: 220V± 22V, 50Hz± 1Hz(110V± 11V, 60Hz)
Operating frequency: 416KHz
Power rating: 1100VA± 10%
Six working modes:
Monopolar Cut
A) Pure cut: 1W~300W( Load 800Ω )
B) Blend1: 1W~250W(Load 800Ω )
C) Blend2: 1W~150W(Load 800Ω )
Monopolar Coag
D) Contact Coag: 1W~80W( Load 800Ω )
E) Forced Coag: 1W~120W( Load 800Ω )
Bipolar
F) Bipolar Coagulation: 1W~50W( Load 200Ω )
G)Bipolar Cut: 1W~120W( Load 200Ω )
Power Consumption: ≤ 1100VA
Configuration Sheet
Electrosurgical Pencil 5pcs
Electrosurgical Pad 10pcs
Electrosurgical pad cable 1pc
Footswitch 1set
Bipolar Forceps and cable 1set
Seven working modes:
Monopolar: Pure cut, blend1, blend2, contact coagulation, forced coagulation
Bipolar: Bipolar coagulation, bipolar cut
The electrosurgical generator is used to control bleeding and surgical cutting in all general and open surgical procedures.
Liquid Crystal Display, with different audible and visual indication during the process of outputting.
Patient return electrode monitoring system and Power Peak System that provides surgeons with improved performance at Lower power settings, minimizing the risk of tissue damage.
Applicable for Prostate Vaporizing Surgical Operation(TUR), perfectly used under water. The electrosurgical generator can be cooperated with, endoscope and laparoscope
Technical Specifications
Power: 220V± 22V, 50Hz± 1Hz(110V± 11V, 60Hz)
Operating frequency: 416KHz
Power rating: 1100VA± 10%
Six working modes:
Monopolar Cut
A) Pure cut: 1W~300W( Load 800Ω )
B) Blend1: 1W~250W(Load 800Ω )
C) Blend2: 1W~150W(Load 800Ω )
Monopolar Coag
D) Contact Coag: 1W~80W( Load 800Ω )
E) Forced Coag: 1W~120W( Load 800Ω )
Bipolar
F) Bipolar Coagulation: 1W~50W( Load 200Ω )
G)Bipolar Cut: 1W~120W( Load 200Ω )
Power Consumption: ≤ 1100VA
Configuration Sheet
Electrosurgical Pencil 5pcs
Electrosurgical Pad 10pcs
Electrosurgical pad cable 1pc
Footswitch 1set
Bipolar Forceps and cable 1set
Related Keywords