Must ISO9001 Factory Low Frequency New Tech 3kw Solar Grid Tie Inverter
- Payment Type:
- L/C, T/T, Western Union
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Shenzhen, China |
---|---|
Payment Type: | L/C, T/T, Western Union |
Product Description
Product Description
Product Description
MUST ISO9001 factory low frequency new tech 3KW solar grid tie inverter
Samples and OEM
Samples are Available for Testing and Market Test. OEM is welcomed for us.
1-Year Warranty on MUST POWER Products
MUST POWER provides a 1-year limited warranty ("Warranty") against defects in materials and workmanship for its Uninterruptible power supply, Power inverter/chargers including inverter12v 24v 48V, Solar charge controllers ("Product").
Guides and After-service Consultancy
Must Power Team will offer these guides below.
A. Need a Accessory
B. Products Repair
C. Power Problems to Solve
D. Power Protection Solutions, etc.
24 Hours After-service consultancy just for you and to make your problems to solve easily.
Want to know more about our Company, Products, Price, Packing, Shipping andany discount? Let's Inquiry NOW !!!!!
Model |
PH30-3KW |
||
Default Battery System Voltage |
48V DC |
||
Charge |
Charge Input |
PV Open Circuit Voltage(VDC) |
145 VDC |
Max PV Input Power(W) |
3200W |
||
Storage Battery Voltage |
Nominal Voltage(VDC) |
48 VDC |
|
Absorption Voltage(VDC) |
54 VDC |
||
Refloat Voltage (VDC) |
54.8 VDC |
||
Float Voltage (VDC) |
57.2 VDC |
||
Low Voltage Protection Point(VDC) |
42 VDC |
||
DC Output |
Output Voltage(VDC) |
40 VDC -57.2 VDC |
|
Max Charging Current(A) |
60 amps continuous @ 40°C ambient |
||
Warning for low voltage(VDC) |
46.0 VDC |
||
Cut off for low voltage(VDC) |
42.0 VDC |
||
Low voltage recovery(VDC) |
46.0 VDC |
||
Display |
LED indication |
Systematic operation, LV indication, LV protection, over charge protection, loads protection, short circuit protection |
|
LCD display |
Charge voltage, charge current, voltage of storage battery, capacity of storage battery, output current |
||
Alarm Protections |
PV array short circuit, PV reverser polarity |
||
Battery reverse polarity, Over charging protection | |||
Output short circuit protection | |||
Low voltage protection for storage battery | |||
Charge mode |
MPPT, PWM, constant current-constant voltage, function of automatic protection for storage battery |
||
Working mode |
Four stage: Absorption CC, Absorption CV, Float CC, Float CV. |
||
|
Peak Conversion efficiency |
98% |
|
inverter |
DC Input |
Rated input voltage(VDC) |
48 VDC |
Allowed input DC voltage scope(VDC) |
40 VDC -- 62 VDC |
||
Voltage scope of starting up equipments(VDC) |
46 VDC -- 58 VDC |
||
LV alarm point(VDC) |
42 VDC |
||
OV alarm point(VDC) |
62 VDC |
||
AC Output |
Rated capacity(VA) |
3750VA |
|
Rated output power(W) |
3000W |
||
Rated output voltage and frequency (Vac/Hz) |
230Vac/50Hz |
||
Rated output current(A) |
13A |
||
Output voltage precision(Vac) |
230 Vac±1% |
||
Output frequency precision(Hz) |
50 Hz±0.1% |
||
Rate of wave distortion(THD) (Linearity loads) |
Off grid≤2% |
||
Grid discharge ≤3% | |||
Grid charge ≤3% | |||
Dynamic response speed(loads 0←→100%) |
20ms |
||
Power factor |
Grid discharge 99.9% |
||
Grid charge 99.9% | |||
Overload capability |
110%,30 minutes |
||
125%,1 minutes | |||
150%,30 seconds | |||
200%,10 seconds | |||
Short circuit 5s | |||
Grid/Off grid change time |
<20ms |
||
Output wave |
sine |
||
Inverting efficiency 80% resistive loads |
≥93% |
||
AC Input |
AC Input maximum of current(A) |
26A |
|
AC Input voltage scope(Vac) |
184Vac -- 253Vac |
||
AC Input frequency scope(Hz) |
47.5Hz -- 51.5Hz |
||
Display |
LED indication |
Systematic operation, indication of charge and discharge, indication of fault |
|
LCD display |
output voltage, output current, grid voltage, grid current, voltage of storage battery, load power, chart of capacity |
||
Protection Function |
Input LV protection |
||
Input OV protection | |||
Output overload protection | |||
Output Short Circuit Protection | |||
Communication |
Communication terminal |
RS485/CAN bus |
|
Mechanical Specifications |
Mounting |
Wall mount |
|
W*H* D(mm)/G.W(kg) |
337*462*183mm/29.5kg |
||
Other |
Operation Temperature Range |
-20ºC -- +50ºC |
|
Environmental Protection Rating |
Indoor(IP20) |
||
Ambient humidity |
0 -- 90% relative humidity(non-condensing) |
||
Altitude |
≤3000m |
Samples and OEM
Samples are Available for Testing and Market Test. OEM is welcomed for us.
1-Year Warranty on MUST POWER Products
MUST POWER provides a 1-year limited warranty ("Warranty") against defects in materials and workmanship for its Uninterruptible power supply, Power inverter/chargers including inverter12v 24v 48V, Solar charge controllers ("Product").
Guides and After-service Consultancy
Must Power Team will offer these guides below.
A. Need a Accessory
B. Products Repair
C. Power Problems to Solve
D. Power Protection Solutions, etc.
24 Hours After-service consultancy just for you and to make your problems to solve easily.
Want to know more about our Company, Products, Price, Packing, Shipping andany discount? Let's Inquiry NOW !!!!!
Related Keywords
Related Keywords
You May Also Like
You May Also Like