Shenzhen Must Power Limited
Shenzhen Must Power Limited
LCD 1kw to 6kw Pure Sine Wave Charger Solar Inverter
  • LCD 1kw to 6kw Pure Sine Wave Charger Solar Inverter
LCD 1kw to 6kw Pure Sine Wave Charger Solar Inverter

LCD 1kw to 6kw Pure Sine Wave Charger Solar Inverter

Payment Type:
L/C, T/T, Western Union, O/A
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: China
Payment Type: L/C, T/T, Western Union, O/A
Product Description
Product Description

Product Description

12/24vdc/48vdc input optional
Max. AC charge current 70A. (Optional)
Inbuilt pure copper transformer
Pure sine wave output
LCD status display
MPPT solar controller Max 60A
50/60Hz automatically
RS232 with free CD(optional)
Battery priority function
Model PV1012C PV1024C PV1512C PV2012C PV2024C PV3012C PV3024C PV3048v PV4024c PV4048C PV5048C PV6048C
Rated Output Power(W) 1000 1500 2000 3000 4000 4000 5000 6000
    Line mode specifications                        
Input Voltage 12V 24V 12V 12V 24V 12V 24V 48V 24V 48V 48V 48V
Input Frequency 50Hz@40-80Hz/60Hz@40-80Hz
Output Voltage Waveform Pure Sine Wave
Output Short Circuit Protection Current limit (Fault after 10s)
    Inverter Mode Specifications                        
Output Voltage Waveform Pure Sine Wave
Power Factor 1
Output Voltage (V) 110Vac/120Vac/220Vac/230Vac ±10%
Output Frequency (Hz) 60Hz ± 0.3Hz / 50Hz ± 0.3Hz
  Auto Tracking Main Frequency  Yes (Following main first connection)  50Hz @40-80Hz  60Hz @40-80Hz
Output Voltage Regulation ±10% rms
Efficiency >80%
Over-Load Protection (110%<load<125%) ±10%: Fault (shutdown output) after 15 minutes; (125%<load<150%) ±10%: Fault (shutdown output) after 60s;
 Load>150 ±10%: Fault (shutdown output) after 20s
Surge Rating 3000VA 4500 6000VA 9000VA 9000VA 12000VA 12000VA 15000VA 18000VA
Capable Of Starting Electric Motor 1HP 1HP 1HP 2HP 2HP 2HP 2HP 3HP 3HP
Inverter Breaker Size 10A 10A 30A 40A
DC Input Voltage 12V 24V 12V 12V 24V 12V 24V 48V 24V/48V 48V
Min DC Start Voltage 11V/22V/43V
Low Battery Alarm 10.5Vdc ± 0.3Vdc for 12V battery  21.0Vdc ± 0.6Vdc for 24V battery  42.0Vdc± 0.6Vdc for 48V battery
Low DC Input Shut-Down 10.0Vdc ± 0.3Vdc for 12V battery  20.0Vdc ± 0.6Vdc for 24V battery 40.0Vdc± 0.6Vdc for 48V battery
High DC Input Alarm & Fault 16.0Vdc ± 0.3Vdc for 12V battery  32.0Vdc ± 0.6Vdc for 24V battery 64.0Vdc± 0.6Vdc for 48V battery
High DC Input Recovery 15.5Vdc ± 0.3Vdc for 12V battery  31.0Vdc ± 0.6Vdc for 24V battery 62.0Vdc± 0.6Vdc for 48V battery
Power Saver Load ≤25W
Charger Mode Specifications                        
Input Voltage 110Vac/120Vac/220Vac/230Vac
Input Voltage Range 96~127Vac/ 155~265Vac
Output Voltage 110Vac/120Vac/220Vac/230Vac ±10%
Charge Current 35A/20A 65A 65A/40A 65A/45A/25A 65A./35A 40A 50A
Charge Current Regulation Charge Current Adjustable: 25%, 50%, 75%, 100%. (Optional)
Battery Initial Voltage 0-15.7Vdc / 31.4Vdc (can operate with 0V battery)
Charger Short Circuit Protection Circuit breaker
Over Charge Protection Bat. V ≥15.7Vdc/ 31.4Vdc , beeps 0.5s every 1s & fault after 60s
General Specifications                        
Certification CE  / ISO9001/Soncap
Operating Temperature Range 0°C to 40°C
Storage Temperature .-15°C to 60 °C 
Operation Humidity 5% to 95%
Audible Noise 60dB max
Cooling Forced air, variable speed fan
  Ctn Size 1000W/1500W/2000W/3000W:570*315*300MM    4000W/5000W/6000W:755*319*288MM
Gross Weight 21KG 26KG 26KG 29.8KG 43.5KG 54.5KG
MPPT solar charger controller function  
Rated voltage 12/24V DC 24/48V DC
Rated charge current  40A 45A 60A 45A 60A 60A
Load current 15A 30A 30A 30A 30A 30A
Input voltage range 15-55V DC 70V~145V
Max. PV open circuit array voltage 55V DC 145V
Typical idle consumption At idle< 30mA
Overload protection(DC load) 2.0 * Inom>5s; 1.5 * Inom>20s; 1.25 * Inom temperature controlled
Bulk charge 14.6V(default) 29.2V(default) 54V 27V 54V 54V 54V
Floating charge 13.4V(default) 26.8V(default) 57.2V 28.6V 57.2V 57.2V 57.2V
Equalization charge 14.0V(default) 28.0V(default) 54.8V 27.4V 54.8V 54.8V 54.8V
Over charge disconnection  14.8V 29.6V 58V 29V 58V 58V 58V
Over charge recovery 13.6V 27.2V 54.8V 27.4V 54.8V 54.8V 54.8V
Over discharge disconnection 10.8V(default) 21.6V(default) 42V 21V 42V 42V 42V
Over discharge reconnection 12.3V 24.6V 46V 23V 46V 46V 46V
Temperature compensation 13.2mV/C 26.4mV/C 39.6mV/C
Lead acid battery settings Adjustable
NiCad battery settings Adjustable
Load control mode  1.Low Voltage Reconnect(LVR):Adjustable;                                                                                            2.Low Voltage Disconnect(LVD):Automatic disconnection; 3.Reconnection:Includes warning flash before disconnect and reconnection 1.PV array short circuit,PV reverser
2.Battery reverse polarity,over charging polarity protection
3.Output short circuit protection
4.Low voltage protection for storage battery
Low voltage reconnect 12.0-14.0Vdc 24.0-28.0Vdc 46V 23V 46V 46V 46V
low voltage disconnet 10.5-12.5Vdc 21.0-25.0Vdc 42-46Vdc 21-23Vdc 42-46Vdc
Ambient temperature 0 to 40°C(full load)  40-60°C(de-rating) .-20°C to 55°C
Altitude Operating5000m, Non-Operating 16000m 3000m
Protection class IP21 IP22
Battery temperature sensor BTS-optional remote battery temperature sensor for increased charging precision
Terminal size(fine/single wire) #8 AWG #6 AWG

Send your message to this supplier

  • Ms. Tina

  • Enter between 20 to 4,000 characters.

Related Keywords

Related Keywords