Shenzhen Must Power Limited
Shenzhen Must Power Limited
Office Us Metal Case Rack Online Pure Sine Wave 1kVA-6kVA UPS
  • Office Us Metal Case Rack Online Pure Sine Wave 1kVA-6kVA UPS
Office Us Metal Case Rack Online Pure Sine Wave 1kVA-6kVA UPS

Office Us Metal Case Rack Online Pure Sine Wave 1kVA-6kVA UPS

Payment Type:
L/C, T/T, D/P, Paypal, Money Gram, Western Union,
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: Shenzhen China
Payment Type: L/C, T/T, D/P, Paypal, Money Gram, Western Union,
Product Description
Product Description

Product Description

Sine wave output, Zero conversion time
Input zero frontline detection function, Bypass output
TVSS function, Input power correct
DC starting, Bypass protection
Automatic startup function, Long-term type power design
Strong ability to recharge long-term acting machine
Shelf-check function, Powerful anti-jamming
Can match generator
Support inductive load too
Winpower2000 monitoring software free downloads
Provide intelligent slot, Provide standard battery pack
Model HR1K HR1KS HR2K HR2KS HR3K HR3KS HR6K HR6KS
CAPACITY 1000VA/700W 2000VA/1400W 3000VA/2100W 6000VA/4200W
INPUT
Phase Single Phase with Ground
Frequency Range 50Hz:46~54Hz
Power Factor >=0.97 >=0.98
Voltage Range  Base on load percentage (100%-80% / 80%-70% / 70%-60% / 60%-0%)
Line Low Transfer 160VAC/140VAC/120VAC/110VAC± 5VAC 176 ±3% VAC
Line Low Comeback 175VAC ± 5VAC 185 ± 3% VAC
Line High Transfer 300VAC± 5VAC 276 ± 3% VAC
Line High Comeback 285VAC± 5VAC 266 ± 3% VAC
OUTPUT
Phase Single
Voltage 220VAC/230VAC/240VAC
Voltage Regulation ± 2% ± 1%
Frequency( Synchronized Range) 46~54Hz
Frequency( Battery Mode) 50 ± 0.2 Hz 50Hz ± 0.5Hz
Current Crest Ratio 3:1
Harmonic Distortion <= 4% THD ( Linear Load) / <= 7% THD ( Non-Linear Load) <= 2% THD (Linear Load)/<= 6%THD(Non-Linear Load)
Output Waveform Pure Sinewave
EFFICIENCY
To AC Mode 85% 85% 85% > 88%
To Battery Mode 83% 83% 83% > 88%
BATTERY
Battery Type 12V/7Ah Depending on the capacity of external batteries 12V/7Ah Depending on the capacity of external batteries 12V/7Ah Depending on the capacity of external batteries 12V/7AH Depending on the capacity of external batteries
Numbers of Batteries 3 8 8 20
Backup Time(Full Load) >5 minutes >9 minutes >5 minutes 8 minutes
Recharge Time 5 hours to 90% 5 hours to 90% 5 hours to 90% 7 hours to 90%
Charging Current (Max.) 1.0A 7A 1.0A 8A+/-1A 1.0A 8A+/-1A 2.0A 4.2A
Charging Voltage 41.1Vdc ± 0.6V 110Vdc ± 0.4V 274Vdc ± 1%V
External Battery type N/A 12V/7AH*3 N/A 12V/7AH*8 N/A 12V/7AH*8 N/A 12V/7AH*20
TRANSFER TIME
AC to DC Zero
Inverter to Bypass 2.5ms (Typical ) Zero
INDICATOR
Status Load Level / Battery Level / Battery Mode / AC Mode / Bypass Mode / Fault
AUDIBLE ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously Sounding
DIMENSION
UPS CaseD x W H(mm) 450x482.6x88 450x482.6x88 600x482.6x130
Battery Case D x W x H N/A 450*482.6*88 450*482.6*88 600*482.6*130
 WEIGHT
UPS Case (kgs) 14(w / battery) 7 34.5(w / Battery) 15 35.5(W / Battery) 16 84(W / Battery) 35
Battery Rack (kgs) N/A 22.5 27.8 27.8 64.2
ENVIRONMENT
Operating Environment 0~40 °C, 20~90% relative humidity (non-condensing)
Noise Level <45dB @ 1 Meter 50dB @ 1 Meter <55dB @ 1 meter
INTERFACE
Smart RS-232 Windows 98/NT/2000/XP/2003, Linux, Sun Solaris, IBM Aix, Compaq True64, SGI IRIX, FreeBSD, HP-UX, and MAC
SNMP (option) Power management from SNMP manager and web browser

Send your message to this supplier

  • Ms. Tina

  • Enter between 20 to 4,000 characters.

Related Keywords

Related Keywords