1-High accuracy and reliability due to the double DSP control system
2-low power consumption up to 94%
3-cold start directly and smart operation for users.
4-simple to install: Capability to install the UPS into any distribution system (neutral not required on rectifier input)
5-capability of regulating the output voltage (to offset voltage drops down long cable runs)
6-built-in automatic and manual battery test feature, battery deep discharge protection and temperature compensating charger
7-back-feed protection: To avoid energy feeding back into the mains supply should a fault occur
8-reliable, filtered, stabilized and regulated sine wave output (double conversion on-line technology )with filters for atmospheric
9-disturbance suppression- high reliability, full microprocessor control with no-break static and manual bypasses, extremely high short-circuit
10-current to ensure compatibility with the most difficult transformer applications (lighting, drives and industrial processes) and an isolation
11-transformer on the inverter output- maximum reliability and power availability- high level diagnostics: Event log with messages, status,
12-measurements and alarms - available from the built-in LCD in several languages
MODEL  EH9115-10K EH9115-20K EH9115-30K EH9115-40K EH9115-60K EH9115-80K
CAPACITY 10KVA/8KW 20KVA/16KW 30KVA/24KW 40KVA/32KW 60KVA/48KW 80KVA/64KW
  INPUT
Voltage 380/400/415 Vac± 20%, 3 Phase +N
Input Frequency 50/60 Hz ± 10%
Power Factor > =0.95
MAX RFI EN50091-2 Class A.
Input voltage protection Electronic Input out of tolerant protection
  OUTPUT
AC Voltage Regulation (Batt. Mode) 380/400/415 Vac ± 1%, 3 Phase +N
Voltage tolerant (balanced load: +/- %1)(unbalanced: +/- %2)(full load: +/-%5)
Voltage regulation time After full load: 25 ms
Frequency Range 50Hz (60Hz special product)
Frequency tolerant (synchron: +/-%2) (free running: +/-%0, 2)
Efficiency (100% load) > 85% > 90%
Harmonic Distortion < =3% THD (Linear Load), < =5% THD(Non Linear Load)
Transfer Time AC to DC Zero
Inverter to Bypass 4 ms (Typical)
Waveform (Batt. Mode)  Pure Sine Wave 
Crest faktor 3: 1
  BATTERY
Battery Type & Numbers Maintenance free lead-acid batteries / 12V x 32pcs
charge current 8A
Battery Start Yes, UPS can be started without AC source.
Battery protection Automatic circuit breaker
Battery voltage protection Electronic 3 level alarms
  OVERLOAD
Overload protection (> 130-%150 load: 60 seconds ) (> %150 load: 30 seconds)
Short circuit protection Electronic protection
Output voltage protection Electronic out of tolerant protection
  PHYSICAL
Dimension, D X W X H (mm) 600*620*1200 600*720*1500
Net Weight (kgs)  200 265 315 342 405 560
  OPERATING ENVIRONMENT 
Humidity 0% - 90% (NonLCCondensing)
Temperature 0 – 40° C
Overtemperature protection Electronic protection
Noise Level  < 58 dBA (At 1 M) < 63 dBA (At 1 M)
Altitude < 1000 M Above Sea Level
LED, LCD, Buzzer YES
  MANAGEMENT 
Remote Control Dry contact, RS232
. All specifications mentioned above are subject to change without prior notice.