2kVA-15kVA Low Frequency 3 Phase UPS
  • 2kVA-15kVA Low Frequency 3 Phase UPS
2kVA-15kVA Low Frequency 3 Phase UPS

2kVA-15kVA Low Frequency 3 Phase UPS

Payment Type:
L/C, T/T, Western Union
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: China
Payment Type: L/C, T/T, Western Union
Product Description
Product Description

Product Description

Reliable, filtered, stabilized and regulated sine wave output (double conversion on-line technology) with filters for atmospheric disturbance suppression

High reliability: Full microprocessor control with no-break static and manual by-pass

High level diagnostics: States, measurements and alarms - available from the built-in LCD

Power factor correction with sinusoidal input to ensure a low impact on the mains supply (UPS input power factor, close to 1) for the single-phase/single-phase series

Very low noise level <40dB(A)

Low power consumption ("Economy Mode", Smart Active Mode, and Standby/Off Mode to increase efficiency up to 98%)

Simple to install:
Easy to position (integrated castors)
Built-in automatic and manual battery test feature
Auto restart on mains return (programmable - software or from the front panel)
Back feed protection as standard: To avoid energy feeding back into the mains supply
Integrated automatic and manual by-pass.
MODEL  EH9115 2K  EH9115 3K EH9115 6K EH9115 10K EH9115 15K
CAPACITY 2KVA/1.4KW  3KVA/2.1KW  6KVA/4.2KW 10KVA/7KW 15KVA/10.5KW
 INPUT 
Voltage  Single phase 220Vac -20% +35%
Voltage Range -15% +25% or -30% + 40% (Input adding AVR function)
Input Frequency 50Hz or 60Hz +/- 5%
 OUTPUT 
AC Voltage Regulation  Single phase 220Vac +/- 5% (adjustable)
Voltage regulation  +/-1%
Frequency Range   50Hz or 60Hz 
Frequency Stability +/- 0.5% (Free Running)
Power Factor  0.7
Transient Response +/- 3% (100% load variation)
Overload Capacity 120% load 30 seconds, >150% constant power.
Transfer Time(AC to DC) Zero 
Waveform   Sinewave THD < 3% at 0-100% linear load
Crest ratio 3:'1
Efficiency (AC to AC) >85%
 BATTERY 
Battery Type Maintenance free lead-acid batteries
DC Voltage 48VDC 192VDC
Charger 5A charger build in ,option 10Acharge
 PROTECTION
Battery Battery low shutdown and breaker
Overload protection 125% 30sec. switch to bypass line & automatic re-transfer
Short circuit protection Current Limited and cut-off and fuse and breaker
UPS Fault Bypass, load supplied from mains less than 2ms.
EMI/EMC EN50091-2, CE Approved
 PHYSICAL
Dimension, D X W X H (mm) 180 x 500 x 540    480 x 845 x 340
Net Weight (kgs)  58 65 82 105 265
 OPERATING ENVIRONMENT 
Humidity  20-90% non-condensing
Temperature 0-40 degree C; 32-104 degree F
Noise Level  Less than 45dB(at 1 meter)
 INTERFACE
Contact Closure Support MEGATEC RUPS UPS monitoring software
RS-232 Support MEGATEC RUPSII / UPSilon 2000 monitoring software
 