Reliable, filtered, stabilized and regulated sine wave output (double conversion on-line technology) with filters for atmospheric disturbance suppression
High reliability: Full microprocessor control with no-break static and manual by-pass
High level diagnostics: States, measurements and alarms - available from the built-in LCD
Power factor correction with sinusoidal input to ensure a low impact on the mains supply (UPS input power factor, close to 1) for the single-phase/single-phase series
Very low noise level <40dB(A)
Low power consumption ("Economy Mode", Smart Active Mode, and Standby/Off Mode to increase efficiency up to 98%)
Simple to install:
Easy to position (integrated castors)
Built-in automatic and manual battery test feature
Auto restart on mains return (programmable - software or from the front panel)
Back feed protection as standard: To avoid energy feeding back into the mains supply
Integrated automatic and manual by-pass.
High reliability: Full microprocessor control with no-break static and manual by-pass
High level diagnostics: States, measurements and alarms - available from the built-in LCD
Power factor correction with sinusoidal input to ensure a low impact on the mains supply (UPS input power factor, close to 1) for the single-phase/single-phase series
Very low noise level <40dB(A)
Low power consumption ("Economy Mode", Smart Active Mode, and Standby/Off Mode to increase efficiency up to 98%)
Simple to install:
Easy to position (integrated castors)
Built-in automatic and manual battery test feature
Auto restart on mains return (programmable - software or from the front panel)
Back feed protection as standard: To avoid energy feeding back into the mains supply
Integrated automatic and manual by-pass.
MODEL | EH9115 2K | EH9115 3K | EH9115 6K | EH9115 10K | EH9115 15K | |
CAPACITY | 2KVA/1.4KW | 3KVA/2.1KW | 6KVA/4.2KW | 10KVA/7KW | 15KVA/10.5KW | |
INPUT | ||||||
Voltage | Single phase 220Vac -20% +35% | |||||
Voltage Range | -15% +25% or -30% + 40% (Input adding AVR function) | |||||
Input Frequency | 50Hz or 60Hz +/- 5% | |||||
OUTPUT | ||||||
AC Voltage Regulation | Single phase 220Vac +/- 5% (adjustable) | |||||
Voltage regulation | +/-1% | |||||
Frequency Range | 50Hz or 60Hz | |||||
Frequency Stability | +/- 0.5% (Free Running) | |||||
Power Factor | 0.7 | |||||
Transient Response | +/- 3% (100% load variation) | |||||
Overload Capacity | 120% load 30 seconds, >150% constant power. | |||||
Transfer Time(AC to DC) | Zero | |||||
Waveform | Sinewave THD < 3% at 0-100% linear load | |||||
Crest ratio | 3:'1 | |||||
Efficiency (AC to AC) | >85% | |||||
BATTERY | ||||||
Battery Type | Maintenance free lead-acid batteries | |||||
DC Voltage | 48VDC | 192VDC | ||||
Charger | 5A charger build in ,option 10Acharge | |||||
PROTECTION | ||||||
Battery | Battery low shutdown and breaker | |||||
Overload protection | 125% 30sec. switch to bypass line & automatic re-transfer | |||||
Short circuit protection | Current Limited and cut-off and fuse and breaker | |||||
UPS Fault | Bypass, load supplied from mains less than 2ms. | |||||
EMI/EMC | EN50091-2, CE Approved | |||||
PHYSICAL | ||||||
Dimension, D X W X H (mm) | 180 x 500 x 540 | 480 x 845 x 340 | ||||
Net Weight (kgs) | 58 | 65 | 82 | 105 | 265 | |
OPERATING ENVIRONMENT | ||||||
Humidity | 20-90% non-condensing | |||||
Temperature | 0-40 degree C; 32-104 degree F | |||||
Noise Level | Less than 45dB(at 1 meter) | |||||
INTERFACE | ||||||
Contact Closure | Support MEGATEC RUPS UPS monitoring software | |||||
RS-232 | Support MEGATEC RUPSII / UPSilon 2000 monitoring software |