Shenzhen Must Power Limited
Shenzhen Must Power Limited
Home UPS 500va to 1500va Full AVR Design for Computer Backup
  • Home UPS 500va to 1500va Full AVR Design for Computer Backup
Home UPS 500va to 1500va Full AVR Design for Computer Backup

Home UPS 500va to 1500va Full AVR Design for Computer Backup

Payment Type:
L/C, T/T, D/P, Western Union
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: China
Payment Type: L/C, T/T, D/P, Western Union
Product Description
Product Description

Product Description

Home ups 500va to 1500va full avr design for computer backup

1. Cpu controlled PWM inverter tech and minimium internal battery of 12V-07ah solves ac-blackout problem
Better, PWM tech inverter provides uninterruptible backup power for load with an instaneously transfer;

2. Full ac input voltage reguator(3-step avr booster/bucker) manages a wider input range, makes ups on
Ac-mode operation longer, protects battery, solves ac-brownout problem better;

3. Led indicator panel, plastic or iron enchrosure option;

4. Widely used in computer, home electronics appliance, small work-station, POS/point of sale etc.
MODEL EA1000-500 EA1000-650 EA1000-800 EA1000-1000
CAPACITY 500VA/300W 650VA/390W 800VA/480W 1000VA/600W
INPUT
Voltage  Nominal Voltage    110/120 VAC or 220/230/240 VAC 
Acceptable Voltage Range 90-145 VAC/150-290 VAC 
Frequency Range 50 /60 Hz
OUTPUT
AC Voltage Regulation (Batt. Mode)  ±10%
Frequency Range (Batt. Mode)  50 Hz or 60 Hz
Transfer Time (Typical) 2-6 ms 
Waveform (Batt. Mode)  Modified Sinewave
BATTERY
Battery Type & Numbers 12 V 7 Ah x 1 12 V 7 Ah x 1 12 V 9 Ah x 1 12 V 7 Ah x 2
Back up Time(at a PC load 8 minuters 10 minuters 20 minuters 20 minuters
Typical Recharge Time 10 hours to 90% after complete discharge
 INDICATORS
AC Mode  Green LED lighting
Battery Mode Green LED flashing every 4 seconds
Low Battery at Battery Mode Green LED flashing every second
Fault Red LED lighting
Battery Fault at AC modes Green LED flashing three times every 2 seconds 
Battery Week at AC modes Red LED flashing every 2 seconds for 30 seconds
Overload Red LED flashing every twice every second
ALARM 
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Fault  Continuously sounding 
PHYSICAL 
Dimension, D X W X H (mm)  295*95*140
Net Weight (kgs) 5.5 6.2 6.8 10.5
ENVIRONMENT 
Humidity  0 to 90% Relative Humidity(Non-condensing)
Operating Temperature 0°Cto 40°C

Send your message to this supplier

  • Ms. Tina

  • Enter between 20 to 4,000 characters.

Related Keywords

Related Keywords