Shenzhen Must Power Limited
Shenzhen Must Power Limited
LCD 500VA/600VA/650VA/800VA/1000VA Line Interactive UPS
  • LCD 500VA/600VA/650VA/800VA/1000VA Line Interactive UPS
LCD 500VA/600VA/650VA/800VA/1000VA Line Interactive UPS

LCD 500VA/600VA/650VA/800VA/1000VA Line Interactive UPS

Payment Type:
T/T, Western Union
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: Shenzhen China
Payment Type: T/T, Western Union
Product Description
Product Description

Product Description

1)Fully digitized microprocessor controlled.
2)LCD series CPU control guarantees high reliability
3)Lightning and surge protection.
4)Cold start function (DC power on).
5)Equipped with AVR to stabilize output voltage wide input voltage range
6)Generator Compatible
7)Auto charging even though the UPS is off
8)Smart RS232 or USB communication interfaces
9)Sealed lead-acid, maintenance free battery
10)Battery low voltage, overload & short circuit protection.
11)Advanced automatic constant charging circuit, prolongs battery life
12)Automatic buck and boost AVR function, wide input voltage 155-280VAC
MODEL EW2110 500 EW2110 600 EW2110 650 EW2110 800 EW2110 1000
CAPACITY 500VA /300W 600VA /360W 650VA /390W 800VA /480W  1000VA /600W 
INPUT
Phase single
Voltage 110/120 VAC or 220/230/240 VAC
Voltage Range 81-145 VAC / 162-290 VAC
Frequency Range 60/50 Hz ±1% (auto sensing)
OUTPUT
Phase single
Voltage (Batt. Mode) 115VAC or 230 VAC
Frequency Range (Batt. Mode) 60 Hz or 50 Hz ±1 Hz
Transfer Time Typical 2-6 ms, 10ms max.
Overload Capability 110% for 5 min, 120% immediate shutdown
Waveform (Batt. Mode)  Modified SineWave
BATTERY
Battery Type & Number 12 V/7 AH x 1 12 V/7 AH x 1 12 V/7 AH x 1 12 V/9 AH x 1 12 V/7 AH x 2
Typical Recharge Time 8 hours to 90% after complete discharge
Backup Time(at a 1 PC load with 15 monitor) 10 minutes 9 minutes 8 minutes 8 minutes 13 minutes
INDICATORS 
LCD Indicator with Blue Back Light The LCD will self turn on when the UPS is functioning including in, off, charging mode and fault mode
PROTECTION
Full Protection Overload, discharge, and overcharge protection
TRANSFER TIME
Typical 2-6ms
ALARM
Battery Mode Sounding every 10 seconds
Low Battery Sounding every second
Overload Sounding every 0.5 second
Battery Replacement Alarm Sounding every 2 seconds
Fault Continuously sounding
PHYSICAL
Dimension, D X W X H (mm) 330 x 100 x 140
Net Weight (kgs) 5.0 6.0 6.5 8.5 10.5
OPERATING ENVIRONMENT
Humidity 0-90 % RH @ 0- 40°C (non-condensing)
Noise Level Less than 40dB
MANAGEMENT
Optional USB/RS-232 Port Supports Windows® 98/2000/2003/XP/Vista/2008, Windows® 7, Linux, and MAC

Send your message to this supplier

  • Ms. Tina

  • Enter between 20 to 4,000 characters.

Related Keywords

Related Keywords