Shenzhen SORO Electronics Co., Ltd.
Shenzhen SORO Electronics Co., Ltd.
High Efficiency Outdoor UPS Hw9110e 1kVA to 10kVA
  • High Efficiency Outdoor UPS Hw9110e 1kVA to 10kVA
High Efficiency Outdoor UPS Hw9110e 1kVA to 10kVA

High Efficiency Outdoor UPS Hw9110e 1kVA to 10kVA

Payment Type:
L/C, T/T
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: China
Payment Type: L/C, T/T
Product Description
Product Description
High Efficiency Outdoor UPS  HW9110E 1KVA to 10KVA

Specifications
Outdoor Online UPS with Air Contioner 
Double conversion online UPS 
IP55 
Be suitable for outdoor severe Temperature 

KEY FEATURES:
1. SORO outdoor Intelligent High Frequency Online UPSS provide continuous pure sine wave AC power supply for outside communications/network equipment.

2. Wall mounted outdoor UPS, Double-conversion online design, high temperature resistant, anti-cold, sealing level for IP31; with the wide range of input voltage and frequency of input window(-45%+35% rated voltage and +-10% rated frequency). In many remote areas of China after a severe test of the grid).

APPLICATIONS:
      This UPS is commonly used in the corner of the city, remote roads, mountains, bad environment, such as high temperature(+50° C)/ low temperature(-40V), severe dust, moisture, rain, mist erosion, every poor power quality(voltage durative higher than 260V or less than 160V, Frequency abnormal change) in the area.








Technical Specifications of Outdoor UPS HW9110E Series



Model
HW9110E 1-10KVA
1KVA        2KVA        3KVA 6KVA 10KVA
Capacity 1KVA/0.7KW 2KVA/1.4KW 3KVA/.1KW 6KVA/4.2KW 10KVA/7KW
Nominal Voltage 220/230/240VAC
Nominal Frequency 50HZ/60HZ
Input
Voltage Range 115~295VAC(±3VAC) 176~297VAC(±3VAC)
Frequency Range 50HZ:(46HZ~54HZ); 60HZ:(56HZ~6HZ)
Soft Start 0~100% 5sec
Power Factor 0.98
Output
Voltage Precision 223/230/240x(1±2%)
Frequency Precision 50/60HZ±0.05HZ
Power Factor 0.7/0.8(Optional) Standard 0.7
Wave Distortion Linear load<3% Non-linear<6%
Overload Capability Overload(110%~150%)for 30 seconds,then automatically transfer to bypass.when load is normal,it can automatically transfer to normal mode.
Crest Factor 3:1
Transfer Time  0MS(AC to DC)
Battery
DC Supply Voltage 36VDC 96VDC 96VDC 240VDC 240VDC
Charge Current   4A/8A(optional)   4A/8A(optional)   4A/8A(optional)      4.2A               4.2A
Internal Battery Caoacity (38/65/80/100AH)optional
Panel Displsy
LED Load level/Battery level,Battry indicator,Unility Power,Bypass,Overload,Fault
Communications
Communicate Interface RS232\SNMP Card(optional)
Work Environment
Temperature -40° C~50° C
Humidity 0~95%(Non-condensing)
Storage Temperature -25° C~55° C
Elevation <1500m
Physical Characterisstics
Weight(KG) N.W 85 125 125 150 155
Dimensions(WxDxH)mm 613x60x954 650x753x1227 650x753x1227 940x940x1770 940x90x1770