Telecom Outdoor High Frequency Online UPS
- Payment Type:
- L/C, T/T
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | China |
---|---|
Payment Type: | L/C, T/T |
Product Description
Product Description
Telecom Outdoor High Frequency Online UPS
KEY FEATURES:
1. Providing with pure sinewave power for outdoor telecom and network equipment.
2. Be suitable for outdoor severe Temperature, Humidity and harsh Environment, especially can meet the outdoor electric network requirements. (Outdoor environment is severe and quality of electric network also is so bad. For example outdoor high temperature is 50 and severe winter is 40, Voltage range is from 160V to 260V even easily change )
3. Adopting sealed natural cold design, high-temperature resistant, cold resistant and corrosion resistant, that degree of sealing is IP55.
4. Providing with the widest input voltage range and input frequency window. (Nominal Voltage: -45% to +35; Nominal Frequency: 10%)
5. Having experiences in remote suburban district in China for years.
Technical Specifications:
KEY FEATURES:
1. Providing with pure sinewave power for outdoor telecom and network equipment.
2. Be suitable for outdoor severe Temperature, Humidity and harsh Environment, especially can meet the outdoor electric network requirements. (Outdoor environment is severe and quality of electric network also is so bad. For example outdoor high temperature is 50 and severe winter is 40, Voltage range is from 160V to 260V even easily change )
3. Adopting sealed natural cold design, high-temperature resistant, cold resistant and corrosion resistant, that degree of sealing is IP55.
4. Providing with the widest input voltage range and input frequency window. (Nominal Voltage: -45% to +35; Nominal Frequency: 10%)
5. Having experiences in remote suburban district in China for years.
Technical Specifications:
Model | HW9110E 1-10KVA | ||||||||||
1KVA | 2KVA | 3KVA | 6KVA | 10KVA | |||||||
Capacity | 1KVA/0.7KW | 2KVA/1.4KW | 3KVA/.1KW | 6KVA/4.2KW | 10KVA/7KW | ||||||
Nominal Voltage | 220/230/240VAC | ||||||||||
Nominal Frequency | 50HZ/60HZ | ||||||||||
Input | |||||||||||
Voltage Range | 115~295VAC(±3VAC) | 176~297VAC(±3VAC) | |||||||||
Frequency Range | 50HZ:(46HZ~54HZ); 60HZ:(56HZ~6HZ) | ||||||||||
Soft Start | 0~100% 5sec | ||||||||||
Power Factor | 0.98 | ||||||||||
Output | |||||||||||
Voltage Precision | 223/230/240x(1±2%) | ||||||||||
Frequency Precision | 50/60HZ±0.05HZ | ||||||||||
Power Factor | 0.7/0.8(Optional) Standard 0.7 | ||||||||||
Wave Distortion | Linear load<3% Non-linear<6% | ||||||||||
Overload Capability | Overload(110%~150%)for 30 seconds,then automatically transfer to bypass.when load is normal,it can automatically transfer to normal mode. | ||||||||||
Crest Factor | 3:1 | ||||||||||
Transfer Time | 0MS(AC to DC) | ||||||||||
Battery | |||||||||||
DC Supply Voltage | 36VDC | 96VDC | 96VDC | 240VDC | 240VDC | ||||||
Charge Current | 4A/8A(optional) | 4A/8A(optional) | 4A/8A(optional) | 4.2A | 4.2A | ||||||
Internal Battery Caoacity | (38/65/80/100AH)optional | ||||||||||
Panel Displsy | |||||||||||
LED | Load level/Battery level,Battry indicator,Unility Power,Bypass,Overload,Fault | ||||||||||
Communications | |||||||||||
Communicate Interface | RS232,SNMP Card(optional) | ||||||||||
Work Environment | |||||||||||
Temperature | -40° C~50° C | ||||||||||
Humidity | 0~95%(Non-condensing) | ||||||||||
Storage Temperature | -25° C~55° C | ||||||||||
Elevation | <1500m | ||||||||||
Physical Characterisstics | |||||||||||
Weight(KG) | N.W | 85 | 125 | 125 | 150 | 155 | |||||
Dimensions(WxDxH)mm | 613x60x954 | 650x753x1227 | 650x753x1227 | 940x940x1770 | 940x90x1770 |