Rok International Industry Co.,Limited
Rok International Industry Co.,Limited
NDIR Infrared Flue Gas Analyzer
  • NDIR Infrared Flue Gas Analyzer
NDIR Infrared Flue Gas Analyzer

NDIR Infrared Flue Gas Analyzer

Payment Type:
T/T, Western Union
Incoterm:
FOB
Min. Order:
1 Set/Sets
Min. Order:
1 Set/Sets
Delivery Time:
20 Days
Transportation:
Ocean, Air
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: Shenzhen
Supply Ability: 18
Payment Type: T/T,Western Union
Incoterm: FOB
Transportation: Ocean,Air
Product Description
Product Description
Portable NDIR Infrared Flue Gas Analyzer for CO ,CO2 ,O2 ,SO2 ,NO2 ,NO
Description:
Comprehensive portable flue gas analyzer adopts the international advanced NDIR non-dispersed infrared technology and electrochemical techniques to measure the volume concentration of CO ,CO2 ,O2 ,SO2 ,NO2 ,NO and other gases in flue gas and to figure out excess air coefficient. This product has high precision, small volume, it is convenient to carry, simple to operate and it is extensively applied in steel, chemical, energy conservation monitoring, energy efficiency evaluation and other fields.
Who need this instruments:?
Combustion and emission control research or certification of Continuous Emission Monitoring System(CEMS), combustion efficiency monitoring for various industrial furnaces or refuse incinerator and boiler.
Features:
1. Simultaneous measurement of O2 ,SO2 ,CO2 ,CO low ,CO high ,HC ,NO ,H2S(optional,NO2(optional) optional T, P, Flow.
2. NDIR-technology to measure CO high, CO2 and HC.
3. Maximum measure 9 gases: six ECD sensors and three NDIR sensors.
4. Auto ZERO function.
5. Built-in pump.
6. Calculation of Lambda and combustion efficiency.
7. LCD 320 x 240 display and RS232 digital output.
8. Weight: 6.5Kgs.
Specifications:

Components

Methods

Normal

Min Range

Max Range

Resolution

Accuracy

O2

Electrochemistry

0-25% vol

0-25% vol

0-100% vol

0.01%

±2%

CO low

Electrochemistry

0-4000ppm

0-100 ppm

0-9999 ppm

1ppm

±2ppm

±10ppm

SO2

Electrochemistry

0-2000ppm

0-100 ppm

0 -4000 ppm

1ppm

±2ppm

±5ppm

NO

Electrochemistry

0-2000ppm

0-100 ppm

0 - 4000 ppm

1ppm

±2ppm

±5ppm

NO2 Optional

Electrochemistry

0-200ppm

0-100 ppm

0 -1000 ppm

1ppm

±2ppm

±5ppm

H2S Optional

Electrochemistry

0-1000ppm

0-200ppm

0- 1000 ppm

1ppm

±2ppm

±5ppm

CO high Optional

NDIR

0-10% vol

/

/

0,01 %

±0,05%

CO2

NDIR

0-25% vol

/

/

0,01 %

±0,05%

HC

NDIR

0-9999ppm

/

/

1ppm

±10ppm

Note: The measured components and range can be customized.

Specification of Temperature Measure

Parameter

Method

Measure Range

Resolution

Precision

Flue Gas Temperature

Thermocouple

0~800℃

1℃

±3℃

Ambient Air Temperature

Thermistor

0~99℃

1℃

±1℃

Other specifications

Communication Interface

RS232

Work Temperature

5~45℃

Relative Humidity

5~85%

Ambient Pressure

86~108kPa

Working power

AC 90V-240 50Hz±1Hz

Dimension

438 X 290 X 152mm(W×L×H)

Weight

About 6.5kg

Send your message to this supplier

  • Mr. Charles

  • Enter between 20 to 4,000 characters.